Cobble Stone Technical
|
Test Type |
Measurement |
Test Size |
Thickness |
AS/NZS Standards |
|
Means Abrasion Index |
2.7 |
300x200 |
40mm |
4456.9-2003 |
|
Mean Breaking Load |
NA |
NA |
NA |
4456.5-2003 |
|
Mean Coefficient of Contraction |
NA |
NA |
NA |
4456.12-2003 |
|
Mean Coefficient of Expansion |
NA |
NA |
NA |
4456.11-2003 |
|
Unconfined Compressive Strength |
45mpa |
115x115 |
40mm |
4456.4 |
|
Initial Rate of Absorption |
0.34(kg/m2/min) |
N/A |
N/A |
4456.17 |
|
Mean Cold Water Absorption Properties |
6.7% |
N/A |
N/A |
4456.14 |
|
Mean Hot Water Absorption Properties |
7.1% |
N/A |
N/A |
4456.14 |
|
Moisture Content & Dry Mass |
Average Wc (Kg/m3) 95 Average Wd 4%5 Average Wa 4.3% Average Dd 2122Kg m3 Average Da 2217K gm3 |
|||
|
Salt Attack |
General Purpose |
N/A |
N/A |
4456.10 |
|
Slip Tests Wet Pendulum |
4586-1999 App A Table2 Class “W” classification low risk of slipping when wet |
|||
Colonialtex Technical
| Test Type |
Measurement |
Test Size |
Thickness |
AS/NZS Standards |
| Means Abrasion Index |
1.9 |
300x200 |
40mm |
4456.9-2003 |
| Mean Breaking Load |
5.7 Kn |
375x375 |
40mm |
4456.5-2003 |
| Mean Coefficient of Contraction |
1.2mm/m |
375x375 |
40mm |
4456.12-2003 |
| Mean Coefficient of Expansion |
1.24 mm/m |
375x375 |
40mm |
4456.11-2003 |
| Unconfined Compressive Strength |
26mpa |
115x115 |
40mm |
4456.4 |
| Initial Rate of Absorption |
0.25(kg/m2/min) |
N/A |
N/A |
4456.17 |
|
Mean Cold Water |
8.2% |
N/A |
N/A |
4456.14 |
|
Mean Hot Water |
8.4% |
N/A |
N/A |
4456.14 |
|
Moisture Content & |
Average Wc (Kg/m3) 95 Average Wd 4.5% |
|||
|
Salt Attack |
General Purpose |
N/A |
N/A |
4456.10 |
|
Slip Tests Wet |
4586-1999 App A |
|||
Henge Stone Technical
| Test Type |
Measurement |
Test Size |
Thickness |
AS/NZS Standards |
| Means Abrasion Index |
1.9 |
300x200 |
40mm |
4456.9-2003 |
| Mean Breaking Load |
5.7 Kn |
375x375 |
40mm |
4456.5-2003 |
| Mean Coefficient of Contraction |
1.2mm/m |
375x375 |
40mm |
4456.12-2003 |
| Mean Coefficient of Expansion |
1.24 mm/m |
375x375 |
40mm |
4456.11-2003 |
| Unconfined Compressive Strength |
26mpa |
115x115 |
40mm |
4456.4 |
| Initial Rate of Absorption |
0.25(kg/m2/min) |
N/A |
N/A |
4456.17 |
|
Mean Cold Water |
8.2% |
N/A |
N/A |
4456.14 |
|
Mean Hot Water |
8.4% |
N/A |
N/A |
4456.14 |
|
Moisture Content & |
Average Wc (Kg/m3) 95 Average Wd 4.5% |
|||
|
Salt Attack |
General Purpose |
N/A |
N/A |
4456.10 |
|
Slip Tests Wet |
4586-1999 App A |
|||