SITE SEARCH

Product of the month

Stackstone

Stackstone

Stackstone is made up of small pieces of irrerular sized natural stone glued together in panels that can be affixed over brick, besser block, blue board or concrete, for both indoor and outdoor use. Stackstone cladding offers a convenient way of accenting retaining walls, pillars or water features.


iPAVE has spent much time in the research and development of our pavers.

Below is a report of the findings from our research. Please feel free to browse and view the technical information below

Cobble Stone Technical

Test Type

Measurement

Test Size

Thickness

AS/NZS Standards

Means Abrasion Index

2.7

300x200

40mm

4456.9-2003

Mean Breaking Load

NA

NA

NA

4456.5-2003

Mean Coefficient of Contraction

NA

NA

NA

4456.12-2003

Mean Coefficient of Expansion

NA

NA

NA

4456.11-2003

Unconfined Compressive Strength

45mpa

115x115

40mm

4456.4

Initial Rate of Absorption

0.34(kg/m2/min)

N/A

N/A

4456.17

Mean Cold Water Absorption Properties

6.7%

N/A

N/A

4456.14

Mean Hot Water Absorption Properties

7.1%

N/A

N/A

4456.14

Moisture Content & Dry Mass

Average Wc (Kg/m3) 95 Average Wd 4%5 Average Wa 4.3% Average Dd 2122Kg m3 Average Da 2217K gm3

Salt Attack

General Purpose

N/A

N/A

4456.10

Slip Tests Wet Pendulum

4586-1999 App A Table2                                                                        Class “W” classification low risk of slipping when wet

 

Colonialtex Technical

Test Type

Measurement

Test Size

Thickness

AS/NZS Standards

Means Abrasion Index

1.9

300x200

40mm

4456.9-2003

Mean Breaking
Load

5.7 Kn

375x375

40mm

4456.5-2003

Mean Coefficient of
Contraction

1.2mm/m

375x375

40mm

4456.12-2003

Mean Coefficient of
Expansion

1.24 mm/m

375x375

40mm

4456.11-2003

Unconfined Compressive
Strength

26mpa

115x115

40mm

4456.4

Initial Rate of Absorption

0.25(kg/m2/min)

N/A

N/A

4456.17

Mean Cold Water
Absorption Properties

8.2%

N/A

N/A

4456.14

Mean Hot Water
Absorption Properties

8.4%

N/A

N/A

4456.14

Moisture Content &
Dry Mass

Average Wc (Kg/m3) 95 Average Wd 4.5%
Average Wa 4.3% Average Dd 2122Kg m3 Average Da 2217 K gm3

Salt Attack

General Purpose

N/A

N/A

4456.10

Slip Tests Wet
Pendulum

4586-1999 App A
Table2

Class “V” classification very low risk of
slipping when wet

 

Henge Stone Technical

Test Type

Measurement

Test Size

Thickness

AS/NZS Standards

Means Abrasion Index

1.9

300x200

40mm

4456.9-2003

Mean Breaking
Load

5.7 Kn

375x375

40mm

4456.5-2003

Mean Coefficient of
Contraction

1.2mm/m

375x375

40mm

4456.12-2003

Mean Coefficient of
Expansion

1.24 mm/m

375x375

40mm

4456.11-2003

Unconfined Compressive
Strength

26mpa

115x115

40mm

4456.4

Initial Rate of Absorption

0.25(kg/m2/min)

N/A

N/A

4456.17

Mean Cold Water
Absorption Properties

8.2%

N/A

N/A

4456.14

Mean Hot Water
Absorption Properties

8.4%

N/A

N/A

4456.14

Moisture Content &
Dry Mass

Average Wc (Kg/m3) 95 Average Wd 4.5%
Average Wa 4.3% Average Dd 2122Kg m3 Average Da 2217 K gm3

Salt Attack

General Purpose

N/A

N/A

4456.10

Slip Tests Wet
Pendulum

4586-1999 App A
Table2

Class “V” classification very low risk of
slipping when wet